NEWSLETTER

| Model | SE 10KTL-D3/G2P | SE 15KTL-D3/G2P | SE 17KTL-D3/G2 | SE 20KTL-D3/G2 | SE 22KTL-D3/G2 | SE 25KTL-D3/G2 | ||
| Efficiency | ||||||||
| Max. Efficiency | 98.4% | |||||||
| Eur. Efficiency | 97.8% | 98.0% | ||||||
| Input (PV) | ||||||||
| Max. Input Voltage | 1100V | |||||||
| Max. PV Configuration | 150% | |||||||
| Rated Input Voltage | 620V | |||||||
| Max. Input Current | 15A/30A | 30A·/30A | ||||||
| Max. Short Circuit Current | 20A/40A | 40A/40A | ||||||
| Start Input Voltage | 180V | |||||||
| MPPT Operating Voltage Range | 160V-1000V | |||||||
| Max. Number of PV Strings | 1/2 | 2/2 | ||||||
| No. of MPPTs | 2 | |||||||
| Output (Grid) | ||||||||
| Rated AC Active Power | 10,000W | 15,000W | 17,000W | 20,000W | 22,000W | 25,000W | ||
| Max. AC Apparent Power | 11,000VA | 16,500VA | 18,700VA | 22,000VA | 24,200VA | 27,500VA | ||
| Max. AC Output Current | 3*16.8A | 3*25.3A | 3*28.6A | 3*33.7A | 3*37A | 3*39.8A | ||
| Rated AC Voltage | 380V/400V/415V, 3W+N+PE | |||||||
| AC Voltage Range① | 260V-510V (Adjustable) | |||||||
| Rated Grid Frequency | 50Hz/60Hz | |||||||
| Grid Frequency Range② | 45Hz-55Hz/55Hz-65Hz (Adjustable) | |||||||
| THDI | <3%@Rated Power | |||||||
| DC Current Injection | <0.5%@Rated Current | |||||||
| Power Factor | > 0.99@Rated power (Adjustable 0.8 LD – 0.8 LG) | |||||||
| Protection | ||||||||
| DC Switch | Yes | |||||||
| Anti-islanding Protection | Yes | |||||||
| AC Overcurrent Protection | Yes | |||||||
| AC Short Circuit Protection | Yes | |||||||
| DC Reverse Connection | Yes | |||||||
| Surge Arrester | DC Type III (Type II optional) / AC Type III (Type II optional) | |||||||
| Insulation Detection | Yes | |||||||
| Leakage Current Protection | Yes | |||||||
| General | ||||||||
| Topology | Transformerless | |||||||
| IP Rating | IP66 | |||||||
| Night Self Consumption | <1W (Standard) | |||||||
| Cooling | Natural cooling | Fan cooling | ||||||
| Operating Temperature Range | -25℃-60℃ | |||||||
| Relative Humidity Range | 0-100% | |||||||
| Max. Operating Altitude | 4000m | |||||||
| Dimensions (W*H*D) | 398mm*460mm*190mm | |||||||
| Weight | 18.7Kg | 20.1kg | 20.3kg | |||||
| HMI & COM | ||||||||
| Display | Wireless & APP+LED, LCD (Optional) | |||||||
| Communication | RS485, Optional:Wi-Fi/GPRS/4G/LAN | |||||||
| Certification | ||||||||
| Safety | IEC 62109-1, IEC 62109-2 | |||||||
| Grid Code | VDE-AR-N 4105, EN 50549-1, CEI 0-21, UNE 206006/206007-1, RD 1699/661&413, IEC 61727/62116, AS 4777.2 | |||||||
| Warranty | 5 Years/10 Years (Optional) | |||||||
Remarks: The range of output voltage and frequency may vary depending on different grid codes.