Solar Energy Storage Inverter
3 phase solar battery inverter is a device that combines a solar inverter and a battery inverter into one unit. This allows the Hybrid Solar Inverter to intelligently process power from solar panels, solar cells and the utility grid simultaneously.
The direct current (DC) power generated by the photovoltaic (PV) system is converted to alternating current (AC) power for use in powering homes. This type of grid-tied solar inverter can also deliver excess power generated to the utility grid.
The process of converting the DC power stored in the solar cell memory to AC power that can be used in the home is managed by the battery inverter.
Specification
Model | SE 5KHB-130-D2/UL | SE 6KHB-130 D2/UL | SE 7K6HB-180 T2/UL | SE 10KHB-210 T2/UL | SE 11K4HB-210 T2/UL |
Efficiency | |||||
Max. Efficiency (PV to AC) | 98.0% | ||||
Max. Efficiency (BAT to AC) | 94.5% | ||||
CEC. Efficiency | 96.5% | ||||
Input (PV) | |||||
Max. PV Input Power | 7,500W | 9,000W | 12,000W | 15,000W | 15,000W |
Max. PV Voltage | 600V | ||||
Start-up Voltage | 90V | ||||
MPPT Operating Voltage Range | 70V-540V | ||||
Max. Input Current per MPPT | 30A/22A | 30A/22A/22A | |||
Max short current per MPPT | 40A/30A | 40A/30A/30A | |||
String per MPPT | 2/2 | 2/2/2 | |||
Nos. of MPPT | 2 | 3 | |||
Input / Output (BAT) | |||||
Battery Type | Lithium-ion/Lead-acid | ||||
Nominal battery voltage | 48V | ||||
Battery voltage range | 40V-64V | ||||
Max. charge/discharge current | 210A/130A | 210A/130A | 210A/180A | 210A/210A | 210A/210A |
Max. charge/discharge power | 10,000W/5,000W | 10,000W/6,000W | 10,000W/7,600W | 10,000W/10,000W | 10,000W/10,000W |
Output (Grid) | |||||
Nominal AC Output Power | 5,000W | 6,000W | 7,600W | 10,000W | 10,000W |
Max. AC Output Apparent power | 5,500VA | 6,600VA | 7,600VA | 11,000VA | 11,400VA |
Max. AC Output Power (PF=1) | 5,500W | 6,600W | 7,600W | 11,000W | 11,400W |
Nominal AC Output Current | 20.9A | 25A | 31.7A | 41.7A | 41.7A |
Max. AC output current | 22.9A | 27.5A | 34.8A | 45.8A | 47.5A |
Nominal Grid Voltage | 120/240V (Split phase) / 208V (2/3 phase) | ||||
Nominal Grid Frequency | 50 Hz /60Hz | ||||
Grid Frequency Range | 45Hz-55Hz/55Hz-65Hz((Adjustable) | ||||
Power Factor | > 0.99 @rated power (Adjustable 0.8 LG – 0.8 LD) | ||||
THDI | <3% (Rated Power) | ||||
Output (Back Up) | |||||
Nominal Output Power | 5,000W | 6,000W | 7,600W | 10,000W | 10,000W |
Max. AC Output Power (PF=1) | 5,500W | 6,600W | 7,600W | 11,000W | 11,400W |
Nominal Output Current | 20.9A | 25A | 31.7A | 41.7A | 41.7A |
Peak Output Apparent Power(1s) | 10,000VA | 12,000VA | 15,200VA | 20,000VA | 20,000VA |
Nominal Output Voltage | 120/240V (Split phase) / 208V (2/3 phase) | ||||
Nominal Output Frequency | 50 Hz /60Hz | ||||
Transfer Time | <10ms(typical) | ||||
THDV | <3% @100% R Load | ||||
Protection | |||||
Protection Category | Class I | ||||
DC Switch | Yes | ||||
Anti-islanding Protection | Yes | ||||
AC Overcurrent Protection | Yes | ||||
DC/AC Overvoltage Protection | DC Type II, AC Type Ⅳ | ||||
AC Short Circuit Protection | Yes | ||||
DC Reverse connection | Yes | ||||
Surge Arrester | DC Type II, AC Type II | ||||
Insulation Resistance Detection | Yes | ||||
Leakage Current Protection | Yes | ||||
AFCI | Yes | ||||
RSD | Yes | ||||
Generator | Yes | ||||
General | |||||
Max. Operation Altitude | 2000m | ||||
Ingress Protection Degree | NEMA 3R | ||||
Operating Temperature Range | -25~60℃(>45℃ derating) | ||||
Relative Humidity | 0~100% | ||||
Cooling Method | Fan Cooling | ||||
Mounting | Wall bracket | ||||
Dimensions (W*H*D) | 16.5*31.5*9.4 inch(420mm*800mm*240mm) | ||||
Weight | 40Kg/88Ib | ||||
PV Connection Way | Terminals | ||||
HMI & COM | |||||
Display | Wireless & APP + LED , LCD (optional) | ||||
Communication Interface | CAN (for BMS), DRM/RS485 (for meter), RS485 , Optional: WiFi /LAN | ||||
Certification | |||||
Grid | UL1741SB, IEEE1547: 2018, HECO SRD 2.0 | ||||
Safety | UL 1741/CSA C22.2/UL 1699B | ||||
EMC | FCC Part 15 Class B | ||||
Warranty | 5 Years |