Model | SE 28KTL-D3 | SE 30KTL-D3 |
Efficiency | ||
Max. Efficiency | 98.6% | 98.6% |
European Efficiency | 98.3% | 98.3% |
Input(PV) | ||
Max. Input Voltage | 1000V | |
Max. PV confifiguration (STC) | 150% | |
Rated Input Voltage | 620V | |
Max. Input Current | 81A (2*40.5A) | |
Max.Short Circuit Current | 90A (2*45A) | |
Start Input Voltage | 250V | |
MPPT Operating Voltage Range | 180V-950V | |
Max. Number of PV Strings | 6(3/3) | |
No. of MPPTs | 2 | |
Output(Grid) | ||
Rated AC Active Power | 28,000W | 30,000W |
Max. AC Apparent Power | 30,800VA | 33,000VA |
Max. AC Active Power (PF=1) | 30,800W | 33,000W |
Max. AC Output Current | 3*45A | 3*48A |
Rated AC Voltage | 380V/400V, 3W+N+PE | |
AC Voltage Range* | 277V-520V (Adjustable) | |
Rated Grid Frequency | 50Hz/60Hz | |
Grid Frequency Range** | 45Hz-55Hz/55Hz-65Hz (Adjustable) | |
THDI | <3% (Rated Power) | |
DC Current Injection | <0.5%In | |
Power Factor | > 0.99 Rated power (Adjustable 0.8 LD – 0.8 LG) | |
Protection | ||
DC switch | Support | |
Anti-islanding protection | Support | |
AC overcurrent protection | Support | |
AC short circuit protection | Support | |
DC reverse connection | Support | |
Surge Arrester | DC type II/AC type II | |
Insulation detection | Support | |
Leakage current protection | Support | |
General | ||
Topology | Transformerless | |
IP Rating | IP65 | |
Night Self Consumption | <1W | |
Cooling | Fan cooling | |
Operating Temperature Range | -25℃-60℃ | |
Relative Humidity Range | 0-100% | |
Max. Operating Altitude | 4000m | |
Noise | <50dB | |
Dimensions (W*H*D) | 555mm*446mm*270mm | |
Weight | 41Kg | |
HMI & COM | ||
Display | Wireless & APP+LED, LCD (Optional) | |
Communication | RS485, Optional :WiFi/GPRS/4G/LAN | |
Certification | ||
Safety | IEC 62109-1,IEC 62109-2 | |
Grid Code | VDE-AR-N 4105, EN 50549-1/2,G99, CEI 0-21/16, UNE 206006/206007-1, UNE 217001, IEC 61727/62116,VDE 0126 | |
Warranty | 5 Years |