Model |
SE 5KHB-130-D2/UL |
SE 6KHB-130-D2/UL |
SE 8KHB-180-T2/UL |
SE 10KHB-210-T2/UL |
Efficiency |
Max. Efficiency (PV To AC) |
98.0% |
Max. Efficiency (BAT To AC) |
94.5% |
Input(PV) |
MAX PV Power |
7500W |
9000W |
12000W |
15000W |
Max. PV Voltage |
600V |
Max Input Current (input A/input B) |
30A/22A |
30A/22A/22A |
Max Short Current (input A/input B) |
40A/30A |
40A/30A/30A |
Start Operating Voltage |
90V |
MPPT Operating Voltage Range |
70V-540V |
No. of MPPT trackers |
2 |
3 |
String per MPP tracker |
2 |
Input (BAT) |
Compatible Battery Type |
Lithium-ion/Lead-acid |
Nominal Battery Voltage |
48V |
Battery Voltage Range |
40V-64V |
Max. Charge/Discharge Current |
210A/130A |
210A/130A |
210A/180A |
210A/210A |
Max. Charge/Discharge Power |
10000W/5000W |
10000W/6000W |
10000W/8000W |
10000W/10000W |
Lithium Battery Charge Curve |
Self-adaption to BMS |
Output (Grid) |
Nominal AC Output Power |
5000W |
6000W |
8000W |
10000W |
Max. AC Output Apparent Power |
5500VA |
6600VA |
8800VA |
11000VA |
Max. AC Output Power (PF=1) |
5500W |
6600W |
8800W |
11000W |
Max. AC Output Current |
25A |
30A |
40A |
50A |
Rated AC Voltage |
120/240V (Split phase) / 230V (Single phase) / 208V (2/3 phase) |
Rated Gird Frequency |
60Hz |
AC Frequency Range |
55Hz-65Hz(adjustable) |
Power Factor |
> 0.99 @rated power (adjustable 0.8 LG – 0.8 LD) |
THDI |
<3% (Rated Power) |
Output (Back Up) |
Nominal Output Power |
5000W |
6000W |
8000W |
10000W |
Nominal Output Current |
20.9A |
25A |
33.4A |
41.7A |
Nominal Output Voltage |
120V / 240V (Split phase) / 230V (Single phase) / 208V (2/3 phase) |
Nominal output frequency |
60Hz |
Transfer Time |
10ms(typ)/ 20ms(max) |
THDV |
<3% @100% R Load |
Protection |
Protection Category |
Class I |
DC Switch |
Support |
Anti-islanding Protection |
Support |
AC Overcurrent Protection |
Support |
AC Short Circuit Protection |
Support |
DC Reverse Connection |
Support |
Surge Arrester |
DC Type II, AC Type II |
Insulation Detection |
Support |
Leakage Current Protection |
Support |
PV Overvoltage Category |
II |
AC Overvoltage Category |
III |
AFCI |
Y |
GEN |
Support |
RSD |
Y (MLRSD Sunspec or Tigo Transmitter) |
General |
Max. Operation Altitude |
2000m |
Noise Emission |
<40dB |
Ingress Protection Degree |
IP65 |
Operating Temperature Range |
-25~60℃ |
Relative Humidity |
0~100% |
Cooling Concept |
Fan Cooling |
Mounting |
Wall bracket |
Dimensions (W*H*D) |
420mm*800mm*240mm |
Weight (kg) |
37 Kg |
PV Connection |
Terminals |
BAT Connection |
DC special connector |
HMI & COM |
Display |
LED+APP |
Communication Interface |
RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/Ethernet |
Certification |
Grid |
UL1741SB, IEEE1547: 2018, HECO SRD 2.0 |
Safety |
UL 1741/CSA C22.2/UL 1699B |
EMC |
FCC Part 15 ClassB |
Warranty |
5 Years/ 10 Years (Optional) |