Inverters for commercial and industrial photovoltaics and battery storage
Saving energy costs and reducing the CO2 footprint are important issues for companies. Three effective ways of achieving greater energy efficiency are: generating and consuming renewable energy through low-maintenance solar PV plants – integrating battery storage systems, e.g. to perform peaking – and reducing the need for expensive reactive power. senergy new energy offers suitable inverters for all these measures.
Be prepared for everything
Simple surge protection
Fireman’s switch can be triggered remotely
DC combiner to prevent AC lines on the roof
Lean solutions for grid and system protection
Compact reactive power inverters for new and existing plants
Model | SE 3K6HB-60 | SE 4K6HB-120 | SE 5KHB-120 | SE 6KHB-120 |
Efficiency | ||||
Max. Efficiency (PV to AC) | 97.3% | |||
Max. Efficiency (BAT to AC) | 94.3% | |||
Input (PV) | ||||
Max. PV Power | 6300W | 9000W | ||
Max. PV Voltage | 550V | |||
Max. Input Current (input A/input B | 15A/15A | |||
Max. Short Current (input A/input B) | 20A/20A | |||
Start Operating Voltage | 90V | |||
MPPT Voltage Range | 70V-520V | |||
No. of MPPT Trackers | 2 | |||
String Per MPP Tracker | 1 | |||
Input (BAT) | ||||
Compatible Battery Type | Lithium-ion/ Lead-acid | |||
Nominal battery voltage | 48V | |||
Battery Voltage Range | 40V-64V | |||
Max. Charge/discharge current | 60A/60A | 120A/120A | 120A/120A | 120A/120A |
Max. Charge/discharge power | 3000W/3000W | 6000W/6000W | 6000W/6000W | 6000W/6000W |
Lithium Battery Charge Curve | Self-adaption to BMS | |||
Output (Grid) | ||||
Nominal AC Output Power | 3600W | 4600W | 5000W | 6000W |
Max. AC Output Apparent Power | 3600VA | 4600VA | 5500VA | 6000VA |
Max. AC Output Power (PF=1) | 3600W | 4600W | 5500W | 6000W |
Max. AC output current | 16A | 22A | 25A | 27.2A |
Rated AC voltage | 230V, L+N+PE | |||
AC Voltage Range | 150V-300V (Adjustable) | |||
Rated Grid Frequency | 50Hz/60Hz | |||
AC Frequency Range | 45Hz-55Hz/55Hz-65Hz (Adjustable) | |||
Grid Connection | Single phase | |||
Power Factor | > 0.99 @rated power (Adjustable 0.8 LD – 0.8 LG) | |||
THDI | <3% (Rated Power) | |||
Output (Back up) | ||||
Nominal Output Voltage | 230V, L+N+PE | |||
Nominal Output Frequency | 50Hz/60Hz | |||
Nominal Output Power | 3000W | 4600W | 5000W | 6000W |
Nominal Output Current | 13A | 20A | 21.7A | 26A |
Maximum Power (1s) | 6000VA | 9200VA | 10000VA | 12000VA |
Nominal Output Voltage | 230V, L+N+PE | |||
Nominal Output Frequency | 50Hz / 60Hz | |||
Transfer Time | 10ms(typ) / 20ms(max) | |||
THDV | <3% @100% R Load | |||
Protection | ||||
Protection Category | Class I | |||
DC Switch | Support | |||
Anti-islanding Protection | Support | |||
AC Overcurrent Protection | Support | |||
AC Short Circuit Protection | Support | |||
DC Reverse Connection | Support | |||
Surge Arrester | DC Type III, AC Type III | |||
Insulation Detection | Support | |||
Leakage Current Protection | Support | |||
PV Overvoltage Category | II | |||
AC Overvoltage Category | III | |||
Gen | Optional | |||
General | ||||
Max. Operation Altitude | 4000m | |||
Noise Emission | <35dB | |||
Ingress Protection Degree | IP65 | |||
Operating Temperature Range | -25℃~60℃ | |||
Relative Humidity | 0~100% | |||
Cooling Concept | Natural Cooling | |||
Mounting | Wall bracket | |||
Dimensions (W*H*D) | 515mm*485mm*175mm | |||
Weight | 20Kg | 25Kg | ||
PV Connection Way | MC4/H4 | |||
Battery Connection Way | Dedicated DC connector | |||
AC Connection Way (grid & back up) | Dedicated AC connector | |||
HMI & COM | ||||
Display | LED+APP | |||
Communication Interface | RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/LAN | |||
Certification | ||||
Grid | VDE-AR-N4105, IEC 61727/62116, AS 4777.2, EN 50549-1,C10/11,G99,CEI 0-21,NRS 097-2-1,RD 1699/661/413 | |||
Safety | IEC 62109-1&2, IEC 62477-1 | |||
Warranty | 5 Years/10 Years (Optional) |